Polymeric distribution-class arresters with UltraSIL polymer housed. Available in Normal Duty, Heavy-Duty and Riser Pole classifications,
-
Tap Changers
Line crews need not be exposed to high voltage conductors and hot transformer fluids
DetailsExternally operated one-, two- and three-phase under-oil tap changer switch family eliminates many of the hazards associated with manual internal tap changing of distribution transformers.
Specifications
- 100 A : 150kV BIL
- 150 A : 150kV BIL
- 300 A : 150kV BIL
Documents
-
Cutouts and Combos
This type L cutouts are available in both polymer and porcelain designs, which provide reliable overcurrent…
DetailsThis type L cutouts are available in both polymer and porcelain designs, which provide reliable overcurrent protection for primary distribution circuits. Overcurrent protection safeguards an electric system from excessive currents produced by abnormal conditions such as faults, line or equipment overloads, or equipment failures.
-
Radiators
Maximum flexibility, available in two types: Integral Header (IHR) (9, 12, and 15 inches wide) and Welded…
DetailsMaximum flexibility, available in two types: Integral Header (IHR) (9, 12, and 15 inches wide) and Welded Header (12 and 15 inches and 520mm wide). The 520mm provides a DIN Standard radiator configured to meet North American requirements. Standard center line mounting lengths range from 21 to 180 inches.
-
Evolution Arrester
Exceeds protective levels offered by standard metal oxide varistor arresters.
DetailsThe Evolution surge arrester uses specially formulated and highly durable Metal Oxide Varistors (MOVs) in combination with a proprietary insulating ceramic ring assembly.
-
Under-oil MOV arrester is designed in accordance with ANSI/IEEE C62.11 heavy-duty distribution class requirements. It is designed for either horizontal or vertical mounting inside the distribution transformer tank to eliminate the difficulties associated with externally mounted arresters.
-
Low Voltage Arrester
Is available in three design configurations: external mount, metal enclosed, and internal mount.
DetailsStormTrapper H.E. (High Energy), low voltage distribution class surge arresters are designed to provide surge protection at distribution transformer secondary bushings, service entrance locations, and any other electrical apparatus connected to a secondary voltage source.
Specifications
- 175 V : 175 V MCOV
- 240 V : 240 V MCOV
- 480 V : 400 V MCOV
- 650 V : 540V MCOV
Documents
-
Polymeric IEC distribution arrester class 1, Use Metal Oxide Varistors (MOVs) having excellent electrical properties, these arresters provide superior overvoltage protection for MV distribution systems.
-
Pressure Relief Valves
ANSI and REA Standards specify pressure relief valves for oil filled equipment.
DetailsThe Heartland pressure relief valve relieves excessive pressure in transformers, regulators and other electrical equipment.
Specifications
- 5 PSI : 35 SCFM
- 10 PSI : 35 SCFM
- 10 PSI : 50 SCFM
- 10 PSI : 60 SCFM
Documents
-
Dual voltage
line crews need not be exposed to high-voltage conductors and hot transformer fluids.
DetailsExternally operated series multiple switch is used to change connection of de-energized transformer windings between series and parallel to provide different common transformer voltage ratios.
Specifications
- 125 KV BIL : 50/100 A
- 150 KV BIL : 150/300/600 A
Documents
-
The IFDTM is a sensor that detects internal arcing faults in distribution transformers. The sensor releases a highly visible orange signal that shows the line worker the transformer status before re-energizing.
-
GreenCap Valves
GreenCapĀ® Series now makes easy to distinguish the NEB fluid filled transformers from the Mineral Oil filled transformers.