ANSI Loadbreak Elbow connectors
Designed in accordance to IEEE Std 386 standard - latest revision.
DetailsLoadbreak Elbow Connector is a fully-shielded and insulated plug-in termination for connecting underground cable to transformers, switching cabinets and junctions equipped with loadbreak bushings.
Specifications
- 200A : 15kV
- 200A : 25kV
- 200A : 35kV
Documents
-
Are designed for use in transformer (mineral) oil, R-Temp® or Envirotemp® FR3® fluid filled padmounted transformers or distribution switchgear
Specifications
- 2 Positions : 550/400/300/65 A
- 4 Positions : 630/400/200 A
Documents
-
Liquid Level gauges
Meets the all requirements of ANSI standard, and industry standard for level indicators.
DetailsLiquid level gauge indicates the oil level in transformers, regulators and other electrical equipment. The tank is normally filled with oil to the 25 degree centigrade level, which is marked on the tank wall.
Specifications
- 1 :
- 1/2 :
- 1.5 :
Documents
-
Tap Changers
Line crews need not be exposed to high voltage conductors and hot transformer fluids
DetailsExternally operated one-, two- and three-phase under-oil tap changer switch family eliminates many of the hazards associated with manual internal tap changing of distribution transformers.
Specifications
- 100 A : 150kV BIL
- 150 A : 150kV BIL
- 300 A : 150kV BIL
Documents
-
Bayonet Fuses
To protect distribution apparatus from damaging currents and to protect distribution systems from failed apparatus.
DetailsIts ideal use is in a two-fuse protection scheme with a current-limiting backup fuse. In this arrangement, secondary faults and overload currents are cleared by the Bay-O-Net fuse, and high level faults are cleared by the current-limiting fuse. The two fuses are connected in series
Specifications
- 8.3 KV - 15.5 KV :
- 23 KV :
- 38 KV :
Documents
-
Magnex Interrupter
The MagneX Interrupter combines safety and efficiency with economic operation.
DetailsOne, Two & Three-Phase Magnex Interrupter. The magnex Interrupter protects distribution transformers from overloads and secondary faults. It can also be utilized as a transformer turn on-off switch.
Specifications
- Single Phase : 10kVA To 167kVA
- Two Phase : 10kVA To 167kVA
- Three Phase : 45kVA To 2000kVA
Documents
-
The bushing well are designed for the termination of primary winding leads at the front plate of fluid-filled apparatus rated at either 8.3/14.4 kV, 15.2/26.3 kV or 16.2/28.0 kV (for Canadian applications).
Specifications
- 15/25/28kV : 125kV BIL
- 35kV : 150kV BIL
Documents
-
The T-connectors are used to terminate high voltage underground cable on deadfront apparatus such as transformers, switches and switchgear. It is fully shielded, submersible.
Specifications
- 125 KV BIL : 15/25 kV Class
- 150 KV BIL : 35 kV Class
Documents
-
ANSI Integral Deadbreak Bushings 600A
Deadbreak apparatus bushing meets the full requirements of IEEE Std 386
DetailsDesigned for sidewall mounting in transformers, switches and other apparatus filled with transformer oil or Envirotemp FR3 Fluid.
Specifications
- 15/25kV : 125kV BIL
- 34.5kV : 150kV BIL & 200 kV BIL
Documents
-
Radiators
Maximum flexibility, available in two types: Integral Header (IHR) (9, 12, and 15 inches wide) and Welded…
DetailsMaximum flexibility, available in two types: Integral Header (IHR) (9, 12, and 15 inches wide) and Welded Header (12 and 15 inches and 520mm wide). The 520mm provides a DIN Standard radiator configured to meet North American requirements. Standard center line mounting lengths range from 21 to 180 inches.
-
Pressure Relief Valves
ANSI and REA Standards specify pressure relief valves for oil filled equipment.
DetailsThe Heartland pressure relief valve relieves excessive pressure in transformers, regulators and other electrical equipment.
Specifications
- 5 PSI : 35 SCFM
- 10 PSI : 35 SCFM
- 10 PSI : 50 SCFM
- 10 PSI : 60 SCFM
Documents
-
It is designed for use in pad mounted or subsurface distribution transformers filled with Envirotemp FR3 fluid, transformer oil or approved equivalent. The assemblies combine the ease of hotstick operation with the safety of deadfront construction.
-
Used in series with a Bay-O-Net type fuse or MagneX Interrupter. Isolation links are not fuses and do not have an interrupting rating. During a transformer failure, the isolation link will melt so that the opened primary circuit of a faulted transformer cannot be re-energized by the line crew.
Documents
-
ELSP Current-limiting Backup Fuse
Used in series with low current primary protection devices.
DetailsThe ELSP fuse is designed for use in transformer oil, Envirotemp FR3 fluid, or an approved equivalent. The fuses highly efficient current limiting section minimizes the effects of high fault current stresses on equipment and the distribution system.
-
The M.O.V.E. Surge Arrester combines metal (zinc) oxide varistor technology in a pre molded rubber elbow to provide overvoltage system protection in an insulated, fully shielded, submersible, deadfront device.
Specifications
- 15 KV Class : 3 To 18 kV
- 25 KV Class : 9 To 21 kV
- 35 KV Class : 18 To 30 kV
Documents
-
Bushing Insert threads into a universal bushing well to provide the same function as an integral loadbreak bushing. Using bushing inserts makes field installation and replacement possible and efficient.
Specifications
- 15 KV Class : 200 A
- 25 KV Class : 200 A
- 28 KV Class : 200A
Documents
-
Dual voltage
line crews need not be exposed to high-voltage conductors and hot transformer fluids.
DetailsExternally operated series multiple switch is used to change connection of de-energized transformer windings between series and parallel to provide different common transformer voltage ratios.
Specifications
- 125 KV BIL : 50/100 A
- 150 KV BIL : 150/300/600 A
Documents
-
Rotatable Feedthru Insert is used to provide dual bushings from a single apparatus bushing well. It makes converting radial-feed transformers to feedthru transformers and adding in-line arrester protection both easy and practical.
Specifications
- 15 KV : 95 kV BIL
- 25 KV : 125 kV BIL
Documents
-
ELX Full Range Fuses
It is ideal for installations where flame discharge and loud operation are undesirable.
DetailsELX fuse is a full range current-limiting fuse designed to provide overcurrent protection. It is completely interchangeable with similar fuses using industry standard clip-style and dry well canister mountings.
Specifications
- 8.3 KV : 3 To 100 A
- 15.5 KV : 3 To 100 A
- 23 KV : 3 To 80 A
Documents
-
NX Fuses
It provide overload protection for all indoor and underground cable dis tribution systems 2.4 through 38 kV.
DetailsNX fuses are noiseless and expel no hot gases or burning particles while interrupting currents from minimum melt to maximum fuse rating (50,000 A through 23 kV, 35,000 A through 27 and 38 kV).
Specifications
- 4.3 KV : 18 To 100 A
- 5.5 KV : 6 To 75 A
- 8.3 KV : 1.5 To 40 A
- 15.5 KV : 1.5 To 40 A
Documents
-
IEC Deadbreak Elbow Connector
Meet the requirements of VDE 0278, IEC 502-4, EDF HN 52-S-61, EEE Std 386 standard, BS 7215 and others.
DetailsFor connection of polymeric cable to transformers, switchgear, motors and other equipment with a premoulded separable connector. For indoor and outdoor installations.
-
For oil-insulated (R-temp, hydrocarbon, or silicon) apparatus, including switchgear, transformers, and capacitors. For indoor and outdoor installations.
Specifications
- 250 A : 24 kV
- 400A : 24/36 kV
- 630 A : 24/36 kV
Documents
-
Measure and indicate the temperature of the oil in transformers, regulators and other electrical equipment. Corrosion resistant Stainless Steel case. High impact resistant UV-stabilized Polycarbonate lens. 2 % accuracy.
-
Cannister Fuse Holder
The drywell cannister and the current limiting fuse provides a versatile serviced current limiting protection system for transformers.
DetailsThe Drywell Current Limiting Fuse Cannister is a removable fuse assembly for use in single and three phase pad-mounted transformers. The fuse well assembly accepts general purpose current limiting fuses and is available in both load-break and dead-break designs.
Specifications
- 8.5 KV Class : 95 kV BIL
- 15 KV Class : 125 kV BIL
- 23 KV Class : 125 kV BIL
Documents
-
The IFDTM is a sensor that detects internal arcing faults in distribution transformers. The sensor releases a highly visible orange signal that shows the line worker the transformer status before re-energizing.
-
GreenCap Valves
GreenCap® Series now makes easy to distinguish the NEB fluid filled transformers from the Mineral Oil filled transformers.
DetailsThis valve is designed specially to be used in transformers filled with natural ester fluids such as the FR3. Ensures compatibility and flow requirements for these fluids.
-
Secondary Bushings are designed for external mounting on distribution transformers filled with transformer oil, R-Temp®, Envirotemp® FR3® Fluid or an approved equivalent.
Documents
-
light-duty under-oil (CLU) MOV arrester
The CLU arrester is compatible with mineral and natural ester oil.
Detailsthe CLU arrester is designed for either horizontal or vertical mounting inside the distribution transformer tank to eliminate the difficulties associated with externally mounted arresters.
Specifications
- Voltage : 3 kV to 36 kV
- MCOV : 2.55 kV to 29 kV
Documents